Help ← Back to Manual Contents


Platinum

Platinum-connections.png

Platinum Connections

  • Professional balanced line audio outputs
    • IMPORTANT: No horn protection on any outputs, inSpire DSP amplifiers or high-pass filter required for horn type loudspeakers
    • OUT A - Outside zone
    • OUT B - Outside zone (optional directional control)
    • MON 1 - Left inside zone for PA or amplified speaker
    • MON 2 - Right inside zone
  • MIDI keyboard Input
    • Keyboard performance recording
    • Standard MIDI jack on rear panel
      • Supports two channels (2nd keyboard dedicated to harp-bell instruments)
    • USB connection will accept a USB controller or MIDI interface
  • Amplifier control supports 2 inSpire amplifiers with fault detection
  • LAN - Wired Ethernet network interface (wired or wireless - WiFi adapter included)
  • Optional wired or optical tower control bells/clock interface
  • AC Input 100-240 VAC 50/60 Hz.
    • Ground required for surge suppression.
    • Uninterruptible power supply (UPS battery backup) is recommended
      • 400VA - Do not plug amplifier into battery backup receptacle, only surge protection

Millennium

Millennium-connections.png

Millennium Connections

  • Professional balanced line audio outputs
    • OUT A - Inside zone for PA or amplified speaker
    • OUT B - Outside zone with horn protection for outdoor speakers
  • MIDI keyboard Input
    • Keyboard performance recording
    • Standard MIDI jack on rear panel
      • Single MIDI channel support (carillon or split on one keyboard)
    • USB connection will accept a USB MIDI keyboard
  • Amplifier control for a single inSpire amplifier
  • LAN - Wired Ethernet network interface (optional WiFi available separately)
  • Optional wired or optical tower control bells/clock interface
  • AC Input 100-240 VAC 50/60 Hz.
    • Ground required for surge suppression.
    • Uninterruptible power supply (UPS battery backup) is recommended
      • 400VA - Do not plug amplifier into battery backup receptacle, only surge protection

Bravo

Bravo-connections.png

Bravo Connections

  • Professional balanced line audio outputs
    • OUT A - Inside zone for PA or amplified speaker
    • OUT B - Outside zone with horn protection for outdoor speakers
  • LAN - Wired Ethernet network interface
  • USB - for optional WiFi adapter only
  • AC Input 100-240 VAC 50/60 Hz.
    • Ground required for surge suppression.
    • Uninterruptible power supply (UPS battery backup) is recommended
      • 400VA - Do not plug amplifier into battery backup receptacle, only surge protection

Tower relay connections

Surge Protection

The low power requirements of the carillon system allows the use of an affordable uninterruptable power supply.

  • Grounded power receptacles are required
  • Separate SURGE ONLY receptacles should be used for amplifiers
  • Back up receptacles should only be used for the carillon ringing controller

Suggested UPS