Platinum
Platinum Connections
- Professional balanced line audio outputs
- IMPORTANT: No horn protection on any outputs, inSpire DSP amplifiers or high-pass filter required for horn type loudspeakers
- OUT A - Outside zone
- OUT B - Outside zone (optional directional control)
- MON 1 - Left inside zone for PA or amplified speaker
- MON 2 - Right inside zone
- MIDI keyboard Input
- Keyboard performance recording
- Standard MIDI jack on rear panel
- Supports two channels (2nd keyboard dedicated to harp-bell instruments)
- USB connection will accept a USB controller or MIDI interface
- Amplifier control supports 2 inSpire amplifiers with fault detection
- LAN - Wired Ethernet network interface (wired or wireless - WiFi adapter included)
- Optional wired or optical tower control bells/clock interface
- AC Input 100-240 VAC 50/60 Hz.
- Ground required for surge suppression.
- Uninterruptible power supply (UPS battery backup) is recommended
- 400VA - Do not plug amplifier into battery backup receptacle, only surge protection
Millennium
Millennium Connections
- Professional balanced line audio outputs
- OUT A - Inside zone for PA or amplified speaker
- OUT B - Outside zone with horn protection for outdoor speakers
- MIDI keyboard Input
- Keyboard performance recording
- Standard MIDI jack on rear panel
- Single MIDI channel support (carillon or split on one keyboard)
- USB connection will accept a USB MIDI keyboard
- Amplifier control for a single inSpire amplifier
- LAN - Wired Ethernet network interface (optional WiFi available separately)
- Optional wired or optical tower control bells/clock interface
- AC Input 100-240 VAC 50/60 Hz.
- Ground required for surge suppression.
- Uninterruptible power supply (UPS battery backup) is recommended
- 400VA - Do not plug amplifier into battery backup receptacle, only surge protection
Bravo
Bravo Connections
- Professional balanced line audio outputs
- OUT A - Inside zone for PA or amplified speaker
- OUT B - Outside zone with horn protection for outdoor speakers
- LAN - Wired Ethernet network interface
- USB - for optional WiFi adapter only
- AC Input 100-240 VAC 50/60 Hz.
- Ground required for surge suppression.
- Uninterruptible power supply (UPS battery backup) is recommended
- 400VA - Do not plug amplifier into battery backup receptacle, only surge protection
Surge Protection
The low power requirements of the carillon system allows the use of an affordable uninterruptable power supply.
- Grounded power receptacles are required
- Separate SURGE ONLY receptacles should be used for amplifiers
- Back up receptacles should only be used for the carillon ringing controller
Suggested UPS
- Tripp Lite BC350 around $60