MagForce motor system installation: Difference between revisions

Overload Single Phase wiring
Line 88: Line 88:


==== Single phase MagForce panel ====
==== Single phase MagForce panel ====
The MagForce control panel for single phase will have a capacitor on the output between outputs ''U'' and ''V''. If the motor is sized to require an overload protector, the ''W'' connection will be routed in a serpentine fashion through the three disconnect circuits. This is required to prevent trips caused by the missing phase detection.
The MagForce control panel for single phase will have a capacitor on the output between outputs ''U'' and ''V''. If the motor is sized to require an overload protector, the ''L1'' connection to the triac input will be routed in a serpentine fashion through the three overload circuits. This is required to prevent trips caused by the missing phase detection.


== Programming Procedure ==
== Programming Procedure ==