Make a record of the following settings for future reference when setup is complete: | Make a record of the following settings for future reference when setup is complete: | ||
;Bell Number | |||
: 1 is the largest bell | |||
;Dimensions | |||
: Air gap between motor and reactor plate (typically 1/4 to 3/8 inch) | |||
: Center of bearing spindle to center of motor | |||
;Swing Angle | |||
: Intended swinging amplitude angle in degrees | |||
;Transmission | |||
: Rotary code wheel to angle ratio | |||
: ''always set to 5.0'' for proximity sensors | |||
;%Start | |||
: Percentage of swing angle for starting pulses | |||
;%Brake | |||
: Percentage of swing angle for braking pulses | |||
;1Oscillation | |||
: Period in milliseconds for one complete swing cycle at 20 degrees of amplitude for proximity sensor calibration | |||
: Reset value is 900, may be less for very small bells, usually higher for most bells | |||
;Pos Option - not used | |||
;PowerStaSwi | |||
: Power reduction using soft-start current limiting 1-8 | |||
: 9=full inrush current which may trip circuit breaker | |||
;Power Brake 1 | |||
: First brake at amplitudes > 20 degrees current limit 1-8 | |||
;Power Brake 2 | |||
: Secondary braking at amplitudes < 20 degrees current limit 1-8 | |||
;StartImp | |||
: Maximum number of impulses allowed before home sensor begins to provide motion feedback | |||
: If no feedback is received after this number of tries, the system will go into safety shutdown | |||
;XtrBrakeImp | |||
: Extra brake impulses after home sensor no longer provides motion feedback | |||
: ''Should be 0'' as blind braking is not advised | |||
;MaxAmpl | |||
: Maximum swinging angle before safety shutdown | |||
: ''Set to 90'' if no obstacles are in the way of the bell swinging high | |||
;P-Regulator | |||
: Proportional regulation factor | |||
;I-Regulator | |||
: Integration regulation factor | |||
: Zero on the terminal when parameters have been successfully calculated and saved | |||
;Pos-Impulse | |||
: Position of the motor impulse in the sweep of the bell | |||
: 0 = home, 100 = turnaround | |||
: ''Always set to 0 for MagForce'' | |||
;Assymmetric | |||
: Proportion of motor pulse for forward/backward balance | |||
: 50 = equal pulses, 100 or 0 = unidirectional drive forward or back | |||