=== Control inputs === | === Control inputs === | ||
Swinging bell control relays in the Chime Master panel are connected to an output terminal labeled Common, | Swinging bell control relays in the Chime Master panel are connected to an output terminal labeled Common, M1, M2, M3 etc. for each bell output. Connect a wire from the relay panel Common to the terminal marked L1-Out in the MagForce control panel. Connect the output relay panel ''Mn'' terminal for each bell to its corresponding ''Sn'' terminal in the MagForce control panel. | ||
Weather-proof toggle switches for each bell are installed on the front panel in parallel with these control inputs for testing in the tower when the controller is disabled. | |||