→Faulty centrifugal Switch: - code disk detail |
|||
| Line 95: | Line 95: | ||
The centrifugal switch is in the control box end of the motor. | The centrifugal switch is in the control box end of the motor. | ||
# Disconnect the wires from the control box in the junction box | # Disconnect the wires from the control box in the junction box. | ||
# Remove PCB from control box | # Remove PCB from control box. | ||
# Remove painted code | # Remove painted code disk. Older motors used plastic disks. Replace with PN 89002052 metal disk and two PN 80850624 set screws. | ||
# Remove four nuts on the standoffs holding the box on the motor | # Remove four nuts on the standoffs holding the box on the motor. | ||
# Remove the four standoffs and nuts holding the end cap on the motor | # Remove the four standoffs and nuts holding the end cap on the motor. | ||
# Cut the terminals off of the two wires going to the plastic switch bracket | # Cut the terminals off of the two wires going to the plastic switch bracket. | ||
# Use a wire nut to connect them together | # Use a wire nut to connect them together. | ||
# Use a wire tie to secure them to the switch bracket | # Use a wire tie to secure them to the switch bracket. | ||
# Reassemble motor by reversing previous steps | # Reassemble motor by reversing previous steps. | ||
# Place a <code><nowiki>C</nowiki></code> label on the control box | # Place a <code>'''<nowiki>C</nowiki>'''</code> label on the control box. | ||
[[Category:Installation]] | [[Category:Installation]] | ||
[[Category:Bell automation]] | [[Category:Bell automation]] | ||
[[Category:Troubleshooting]] | [[Category:Troubleshooting]] | ||