IntelliSwing 2052 motor installation: Difference between revisions
Motor winding connections corrections |
|||
| Line 22: | Line 22: | ||
=== Rotation === | === Rotation === | ||
The motor is driven by the circuit in only one direction. Direction of rotation is determined by tying combinations of motor starting winding wires together as shown in the wiring diagram. | The motor is driven by the circuit in only one direction. Direction of rotation is determined by tying combinations of motor starting winding wires together as shown in the wiring diagram. Wire nuts in the j-box are labeled on the diagram as '''MA''', '''MB''' and '''MC''' for direction selection. See the diagrams for clarification. | ||
Wire nut '''MA''' always has a red wire from the control box and a yellow wire from the motor windings. | * Wire nut '''MA''' always has a red wire from the '''control box''' and a yellow wire from the motor windings. | ||
* Wire nut '''MB''' always has a blue wire from the motor windings. | |||
* Wire nut '''MC''' always has a white and an orange wire from the motor windings. | |||
The remaining motor winding wires are red and black. Rotation is as viewed from the control box end of the motor. | |||
* For clockwise rotation, the red motor winding wire ties to '''MA''' and '''MC''' gets the black wire. | |||
The remaining motor winding wires are red and black. | * For counter-clockwise rotation, black ties to '''MA''' and '''MC''' gets the red motor winding wire. | ||
=== Control chip === | === Control chip === | ||