IntelliSwing 2052 motor installation: Difference between revisions
| Line 60: | Line 60: | ||
==== Motor appears to be dead ==== | ==== Motor appears to be dead ==== | ||
Open the junction box and re-make all wire nut connections, cutting and stripping oxidized wires. Use quality brass set-screw type wire nuts. | * Open the junction box and re-make all wire nut connections, cutting and stripping oxidized wires. Use quality brass set-screw type wire nuts. | ||
* Check the 1/4A fuse on the control PCB inside the motor control housing. If it is blown, the '''PWR''' light will not come on. | |||
* Try connecting the violet ''K-lead'' to '''L2''' (with circuit breaker off). If the motor runs when power is turned on, then the problem is with the control line going to the ''K-lead''. Check relay panels or switches. | |||
==== Motor rotates but bell doesn't move ==== | ==== Motor rotates but bell doesn't move ==== | ||