Rear panel AX: Difference between revisions
mNo edit summary |
|||
(5 intermediate revisions by the same user not shown) | |||
Line 3: | Line 3: | ||
== Platinum == | == Platinum == | ||
[[File:Platinum-connections.png| | [[File:Platinum-connections.png|800px|frameless]] | ||
=== Platinum Connections === | |||
* Professional balanced line audio outputs | * Professional balanced line audio outputs | ||
** IMPORTANT: No horn protection on any outputs, inSpire DSP amplifiers or high-pass filter required for horn type loudspeakers | ** IMPORTANT: No horn protection on any outputs, inSpire DSP amplifiers or high-pass filter required for horn type loudspeakers | ||
Line 20: | Line 20: | ||
* '''LAN''' - Wired Ethernet network interface (wired or wireless - WiFi adapter included) | * '''LAN''' - Wired Ethernet network interface (wired or wireless - WiFi adapter included) | ||
* Optional wired or optical '''tower control''' bells/clock interface | * Optional wired or optical '''tower control''' bells/clock interface | ||
* '''AC Input''' 100-240 VAC 50/60 Hz. | |||
** Ground required for surge suppression. | |||
** Uninterruptible power supply (UPS battery backup) is recommended | |||
*** 400VA - Do not plug amplifier into battery backup receptacle, only surge protection | |||
== Millennium == | == Millennium == | ||
[[File:Millennium-connections.png| | [[File:Millennium-connections.png|800px|frameless]] | ||
=== Millennium Connections === | |||
* Professional balanced line audio outputs | * Professional balanced line audio outputs | ||
** '''OUT A''' - Inside zone for PA | ** '''OUT A''' - Inside zone for PA or amplified speaker | ||
** '''OUT B''' - Outside zone with horn protection for outdoor speakers | ** '''OUT B''' - Outside zone with horn protection for outdoor speakers | ||
* '''MIDI keyboard''' Input | * '''MIDI keyboard''' Input | ||
Line 36: | Line 40: | ||
* '''LAN''' - Wired Ethernet network interface (optional WiFi available separately) | * '''LAN''' - Wired Ethernet network interface (optional WiFi available separately) | ||
* Optional wired or optical '''tower control''' bells/clock interface | * Optional wired or optical '''tower control''' bells/clock interface | ||
* '''AC Input''' 100-240 VAC 50/60 Hz. | |||
** Ground required for surge suppression. | |||
** Uninterruptible power supply (UPS battery backup) is recommended | |||
*** 400VA - Do not plug amplifier into battery backup receptacle, only surge protection | |||
== Bravo == | == Bravo == | ||
[[File:Bravo-connections.png| | [[File:Bravo-connections.png|800px|frameless]] | ||
=== Bravo Connections === | |||
* Professional balanced line audio outputs | * Professional balanced line audio outputs | ||
** '''OUT A''' - Inside zone for PA | ** '''OUT A''' - Inside zone for PA or amplified speaker | ||
** '''OUT B''' - Outside zone with horn protection for outdoor speakers | ** '''OUT B''' - Outside zone with horn protection for outdoor speakers | ||
* '''LAN''' - Wired Ethernet network interface | * '''LAN''' - Wired Ethernet network interface | ||
* '''USB''' - for optional WiFi adapter only | * '''USB''' - for optional WiFi adapter only | ||
* '''AC Input''' 100-240 VAC 50/60 Hz. | |||
** Ground required for surge suppression. | |||
** Uninterruptible power supply (UPS battery backup) is recommended | |||
*** 400VA - Do not plug amplifier into battery backup receptacle, only surge protection | |||
== Surge Protection == | |||
The low power requirements of the carillon system allows the use of an affordable uninterruptable power supply. | |||
* Grounded power receptacles are required | |||
* Separate SURGE ONLY receptacles should be used for amplifiers | |||
* Back up receptacles should only be used for the carillon ringing controller | |||
Suggested UPS | |||
* [https://tripplite.eaton.com/bc-personal-120v-350va-180w-standby-ups-ultra-compact-desktop-6-outlets~BC350 Tripp Lite BC350] around [https://www.amazon.com/Tripp-Lite-BC350-Desktop-Battery/dp/B000B8MFI6 $60] | |||
[[Category:AX Products]] | [[Category:AX Products]] | ||
[[Category:AX Manual]] | [[Category:AX Manual]] |
Latest revision as of 14:47, 26 May 2023
Help ← Back to Manual Contents
Platinum
Platinum Connections
- Professional balanced line audio outputs
- IMPORTANT: No horn protection on any outputs, inSpire DSP amplifiers or high-pass filter required for horn type loudspeakers
- OUT A - Outside zone
- OUT B - Outside zone (optional directional control)
- MON 1 - Left inside zone for PA or amplified speaker
- MON 2 - Right inside zone
- MIDI keyboard Input
- Keyboard performance recording
- Standard MIDI jack on rear panel
- Supports two channels (2nd keyboard dedicated to harp-bell instruments)
- USB connection will accept a USB controller or MIDI interface
- Amplifier control supports 2 inSpire amplifiers with fault detection
- LAN - Wired Ethernet network interface (wired or wireless - WiFi adapter included)
- Optional wired or optical tower control bells/clock interface
- AC Input 100-240 VAC 50/60 Hz.
- Ground required for surge suppression.
- Uninterruptible power supply (UPS battery backup) is recommended
- 400VA - Do not plug amplifier into battery backup receptacle, only surge protection
Millennium
Millennium Connections
- Professional balanced line audio outputs
- OUT A - Inside zone for PA or amplified speaker
- OUT B - Outside zone with horn protection for outdoor speakers
- MIDI keyboard Input
- Keyboard performance recording
- Standard MIDI jack on rear panel
- Single MIDI channel support (carillon or split on one keyboard)
- USB connection will accept a USB MIDI keyboard
- Amplifier control for a single inSpire amplifier
- LAN - Wired Ethernet network interface (optional WiFi available separately)
- Optional wired or optical tower control bells/clock interface
- AC Input 100-240 VAC 50/60 Hz.
- Ground required for surge suppression.
- Uninterruptible power supply (UPS battery backup) is recommended
- 400VA - Do not plug amplifier into battery backup receptacle, only surge protection
Bravo
Bravo Connections
- Professional balanced line audio outputs
- OUT A - Inside zone for PA or amplified speaker
- OUT B - Outside zone with horn protection for outdoor speakers
- LAN - Wired Ethernet network interface
- USB - for optional WiFi adapter only
- AC Input 100-240 VAC 50/60 Hz.
- Ground required for surge suppression.
- Uninterruptible power supply (UPS battery backup) is recommended
- 400VA - Do not plug amplifier into battery backup receptacle, only surge protection
Surge Protection
The low power requirements of the carillon system allows the use of an affordable uninterruptable power supply.
- Grounded power receptacles are required
- Separate SURGE ONLY receptacles should be used for amplifiers
- Back up receptacles should only be used for the carillon ringing controller
Suggested UPS
- Tripp Lite BC350 around $60