[[File:2052-jb-ccw.png|thumb|Counter-Clockwise wiring]]
Click to open in your browser or right click to save link (download):


Click to open in your browser or right click to download and save:
* [[Media:2052MotorWiring.pdf|intelliSwing 2052 motor hookup (PDF)]]
 
* [[Media:2052MotorInstallation.pdf|intelliSwing 2052 motor installation overview (PDF)]]
* [[Media:2052MotorWiring.pdf|intelliSwing 2052 motor hookup (PDF download)]]
* [[Media:ChainStud.pdf|intelliSwing 2052 chain bracket detail (PDF)]]
* [[Media:2052MotorInstallation.pdf|intelliSwing 2052 motor installation overview (PDF download)]]
* [[Media:2052ChipInstallation.pdf|intelliSwing 2052 motor chip instructions (PDF)]]
* [[Media:ChainStud.pdf|intelliSwing 2052 chain bracket detail (PDF download)]]
* [[Media:2052sch.pdf|intelliSwing 2052 motor schematic diagram (PDF)]]
* [[Media:2052ChipInstallation.pdf|intelliSwing 2052 motor chip instructions (PDF download)]]
* [[Media:2052sch.pdf|intelliSwing 2052 motor schematic diagram (PDF download)]]


== Theory of operation ==
== Theory of operation ==
Line 25: Line 25:


* Wire nut '''MA''' always has a red wire from the '''control box''' and a yellow wire from the motor windings.
* Wire nut '''MA''' always has a red wire from the '''control box''' and a yellow wire from the motor windings.
* Wire nut '''MB''' always has a blue wire from the motor windings.
* Wire nut '''MB''' always has a blue wire from the motor windings and '''L2''' from the power disconnect.
* Wire nut '''MC''' always has a white and an orange wire from the motor windings.
* Wire nut '''MC''' always has a white and an orange wire from the motor windings.


Line 95: Line 95:


The centrifugal switch is in the control box end of the motor.  
The centrifugal switch is in the control box end of the motor.  
# Disconnect the wires from the control box in the junction box
# Disconnect the wires from the control box in the junction box.
# Remove PCB from control box
# Remove PCB from control box.
# Remove painted code wheel
# Remove painted code disk. Older motors used plastic disks. Replace with PN 89002052 metal disk and two PN 80850624 set screws.
# Remove four nuts on the standoffs holding the box on the motor
# Remove four nuts on the standoffs holding the box on the motor.
# Remove the four standoffs and nuts holding the end cap on the motor
# Remove the four standoffs and nuts holding the end cap on the motor.
# Cut the terminals off of the two wires going to the plastic switch bracket
# Cut the terminals off of the two wires going to the plastic switch bracket.
# Use a wire nut to connect them together
# Use a wire nut to connect them together.
# Use a wire tie to secure them to the switch bracket
# Use a wire tie to secure them to the switch bracket.
# Reassemble motor by reversing previous steps
# Reassemble motor by reversing previous steps.
# Place a <code><nowiki>C</nowiki></code> label on the control box
# Place a <code>'''<nowiki>C</nowiki>'''</code> label on the control box.