Bell Control Technical Data 3700: Difference between revisions
Test combo output transistor |
|||
| (5 intermediate revisions by the same user not shown) | |||
| Line 48: | Line 48: | ||
=== Module Address Switch === | === Module Address Switch === | ||
Module addresses are human readable (not binary). The switches are numbered 1 to 3 left to right at the top of each module. Set module 4 as 3+1, module 5 as 3+2. | Module addresses are human readable (not binary). The switches are numbered 1 to 3 left to right at the top of each module. Set module 4 as 3+1, module 5 as 3+2. | ||
For single panels needing 25 to 32 note outputs, module number 7 (switches 1+2 ON) and 8 (all switches ON) will be specified, but these addresses are generally reserved for Combo modules. | |||
==== Non-musical controls ==== | ==== Non-musical controls ==== | ||
| Line 102: | Line 104: | ||
Four wires (two twisted pairs) are enough unless AX STATUS mode is used (not implemented at the time of this writing). | Four wires (two twisted pairs) are enough unless AX STATUS mode is used (not implemented at the time of this writing). | ||
# STAT+ ( | # STAT+ (not used) | ||
# STAT- | # STAT- | ||
# 12V+ (used to power the isolated inteface in the controller) | # 12V+ (used to power the isolated inteface in the controller) | ||
# 12V- (data | # 12V- (isolated data common and interface power - NOT Earth or cable shield) | ||
# DATA+ (control data from the controller) | # DATA+ (control data from the controller) | ||
# DATA- | # DATA- | ||
| Line 238: | Line 240: | ||
Does not affect motor enable outputs to intelliSwing panels, but will affect Relay modules if used to trigger striker outputs. | Does not affect motor enable outputs to intelliSwing panels, but will affect Relay modules if used to trigger striker outputs. | ||
Available striker pulse times (milliseconds - setting is indicated by blinking Input LED): | |||
:75 - one blink - only for very small bells in chimes and carillons for faster repeat | :75 - one blink - only for very small bells in chimes and carillons for faster repeat | ||
:100 - two blinks - (Carillon panel 3 default) | :100 - two blinks - (Carillon panel 3 default) | ||
| Line 250: | Line 252: | ||
Click the Step button to get to desired bell output, then long press Step or Repeat until Input LED indicates new pulse width. | Click the Step button to get to desired bell output, then long press Step or Repeat until Input LED indicates new pulse width. | ||
* Long Press Step - (up) lengthen output pulse | * Long Press Step - (up) lengthen output pulse | ||
* Long Press Repeat - (down) shorten pulse | * Long Press Repeat - (down) shorten pulse | ||
* Click Repeat - re-test using new pulse | * Click Repeat - re-test using new pulse | ||
* Long Press Test - saves newly selected timing for all bells before exiting self test | * Long Press Test - saves newly selected timing for all bells before exiting self test | ||
** During save, Input LED blinks four times | ** During save, Input LED blinks four times | ||
* Double click Test - revert to last saved pulse times (losing any recent changes) | |||
If you want to reset to default pulse times | If you want to reset to default pulse times to factory defaults: | ||
* Change the module configuration | * Change the module configuration as follows | ||
** Power off the panel | |||
** Unplug ribbon bus from one of the modules | |||
** Power on, wait for two seconds and power back off | |||
** Plug the ribbon bus back into the module | |||
** Power on the panel | |||
== Other applications == | == Other applications == | ||
=== Minute impulse clocks === | === Minute impulse clocks === | ||
This application requires a | This application requires a 3721 combo module with dry contacts to switch the voltage to the minute impulse clock movements. | ||
* set all three Panel address switches ON | * set all three Panel address switches ON | ||
* set high baud ON | * set map switch 4 ON | ||
* output | * set high baud ON if system plays music (speakers or bell clappers) | ||
* output | * output 2 N.O. is odd minutes | ||
* | * output 3 N.O. is even minutes | ||
* a single DC tolling hammer output is provided to ring the hour | |||
=== Deagan Damper relay === | === Deagan Damper relay === | ||
| Line 300: | Line 307: | ||
** The voltage drop should be around 0.5 Volts - shorted outputs will be near 0 Volts (and fuse will be blown - do not replace) | ** The voltage drop should be around 0.5 Volts - shorted outputs will be near 0 Volts (and fuse will be blown - do not replace) | ||
** Return the module to Chime Master for replacement/rework if any measurement is less than 0.35 Volts | ** Return the module to Chime Master for replacement/rework if any measurement is less than 0.35 Volts | ||
=== Combo Module === | |||
To test the striker output of the Combo module, use the steps above as for the DC Striker Module. | |||
* Hold the red meter probe to the bottom of the striker fuse | |||
* Touch the black meter probe to the middle lead of Q1 | |||
** The voltage drop should be around 0.5 Volts - shorted outputs will be near 0 Volts (and fuse will be blown - do not replace) | |||
[[Category:Installation]] | [[Category:Installation]] | ||
[[Category:Troubleshooting]] | [[Category:Troubleshooting]] | ||