MagForce motor system installation: Difference between revisions

Line 102: Line 102:
* If the bell seems to be fighting itself to get started, experiment with %Start.
* If the bell seems to be fighting itself to get started, experiment with %Start.
* If you get ‘ErrBlo’ (blocked bell), maybe it needs more pulses to start, try increasing StaImp
* If you get ‘ErrBlo’ (blocked bell), maybe it needs more pulses to start, try increasing StaImp
* When ’Restart’ appears on the display, the system has calculated the ideal impulse (middle value on the lower line on the status screen) to swing the bell. If you would like the bell to swing higheror lower, try other values for Angle and MaxAmpli. It will recalculate the ideal impulse based on changes you make at this time.
* When ’Swing’ appears on the display, the system has calculated the ideal impulse (middle value on the lower line on the status screen) to swing the bell. If you would like the bell to swing higheror lower, try other values for Angle and MaxAmpli. It will recalculate the ideal impulse based on changes you make at this time.
*  When you like the angle and the display again says ‘Swing’ you can press ON to stop the bell swinging. Wait for the bell to come to a full stop.
*  When you like the angle and the display again says ‘Swing’ you can press ON to stop the bell swinging. Wait for the bell to come to a full stop.
*  The terminal display will indicate ‘Restart’ to indicate that the experiment is not yet complete.
*  The terminal display will indicate ‘Restart’ to indicate that the experiment is not yet complete.