Bell Control Technical Data 3700: Difference between revisions
| Line 61: | Line 61: | ||
Address the modules left to right from 0 up to 4 (five modules maximum) | Address the modules left to right from 0 up to 4 (five modules maximum) | ||
==== | ==== Carillon panels ==== | ||
Carillon panels come in three sizes. | |||
===== Five output modules ===== | |||
Three 20 output panels support five octaves minus one semitone. Address the modules from 1 to 5: | |||
* Panel 1 skips first semitone for notes C to G# | |||
* Panel 2 outputs notes A to E | |||
* Panel 3 outputs notes F to C | |||
===== Six output modules ===== | |||
Three 24 output panels support six octaves fully chromatic. Address the modules from 0 to 5: | |||
* Panel 1 outputs notes C to B (first two octaves) | |||
* Panel 2 outputs notes C to B (third and fourth octaves) | |||
* Panel 3 outputs notes F to C (fifth and sixth octaves) | |||
===== Seven or eight output modules ===== | |||
From 25 to 32 fully chromatic outputs on a single panel. Address the modules from 0 to 7: | |||
* Module 6: 1 and 2 ON | * Module 6: 1 and 2 ON | ||
* Module 7: 1, 2 and 3 ON | * Module 7: 1, 2 and 3 ON | ||
== Installation == | == Installation == | ||