Line 198: Line 198:
** The voltage drop should be around 0.5 Volts - shorted outputs will be near 0 Volts (and fuse will be blown - do not replace)
** The voltage drop should be around 0.5 Volts - shorted outputs will be near 0 Volts (and fuse will be blown - do not replace)
** Return the module to Chime Master for replacement/rework if any measurement is less than 0.35 Volts
** Return the module to Chime Master for replacement/rework if any measurement is less than 0.35 Volts
== Other applications ==
=== Minute impulse clocks ===
This application requires a quad relay module with dry contacts to switch the voltage to the clock movements. Standard firmware supports minute impulse.
* set all three Panel address switches ON
* set high baud ON for AX, OFF for LX
* output 1 is odd minutes
* output 2 is even minutes
=== Deagan Damper relay ===
This relay panel supports up to 32 Damper outputs to be used in conjunction with a striker panel for single tone or harmonic Deagan Tower Chimes. We have improved upon Deagan's model 72-74 mechanical relays in conjunction with our Libertas AX controller.
* Harmonic bells supported with a sustain pedal that works like a piano during chord changes
* Single tone (melody only) playing never requires sustain pedaling or legato keying
This application requires DAMPER firware installed on the interface module.
* set all three Panel address switches OFF
* set map switch 4 ON
* set high baud ON (only available with AX controller)


== Repairs ==
== Repairs ==