Bell Control Technical Data 3700: Difference between revisions
numbered pinout |
|||
| Line 73: | Line 73: | ||
=== LX Systems === | === LX Systems === | ||
Sufficient power is available from the 12V terminals of the interface | Sufficient power is available from the 12V terminals of the interface to operate the LX control panel. If the data cable length causes the supply voltage to drop so that the LX control panel does not operate, try the following remedies. | ||
* Use additional spare wires in the data cable to carry more current. | |||
* Plug a booster power suppply into the 12VDC input of the control panel. | |||
# STAT+ (not used) | |||
# STAT- (not used) | |||
# 12V+ (connect to P+ terminal 4 on LX controller) | |||
# 12V- (connect to P- terminal 5 on LX controller) | |||
# DATA+ (connect to T+ terminal 1 on LX controller) | |||
# DATA- (connect to T- terminal 2 on LX controller) | |||
== Troubleshooting == | == Troubleshooting == | ||