Bell Control Technical Data 3700: Difference between revisions

mNo edit summary
Line 72: Line 72:
Interface module
Interface module
[[File:BC-CIF-3703-TestButton.png|400px|thumb|right|Long press to test]]
[[File:BC-CIF-3703-TestButton.png|400px|thumb|right|Long press to test]]
* Active - indicates the high voltage relays are enabled. Indicated from logic before drive transistor.
* ACTIVE: indicates the high voltage relays are enabled. Indicated from logic before drive transistor.
** Active only on when outputs are active. Resets at end of concert.
** Active only on when outputs are active. Resets at end of concert.
* Power - 12VDC Power supply from Power Supply Module is on and 5V regulator is OK.
* POWER: 12VDC Power supply from Power Supply Module is on and 5V regulator is OK.
** Should be as bright as power light on Power module.
** Should be as bright as power light on Power module.
* Test Mode - indicates self test is active. Inputs are ignored.
* TEST MODE: indicates self test is active. Inputs are ignored.
* Signal - blinks with input data.
* SIGNAL: blinks with input data.
** Should never be constantly lit except dim glow in Bit Map mode.
** Should never be constantly lit except dim glow in Bit Map mode.
** Blinks brighter when receiving low Baud signal.
** Blinks brighter when receiving low Baud signal.
* Input - indicates that input data addressed to this panel, or
* INPUT: indicates that input data addressed to this panel, or
** Steady Blink if configuration switch error.
** Steady Blink if configuration switch error.
** Will not blink if incoming activation data is for this panel, but no module has been installed for it.
** Will not blink if incoming activation data is for this panel, but no module has been installed for it.
* Output - indicates that this panel is sending status back to the controller.
* OUTPUT: indicates that this panel is sending status back to the controller.
** Blinks brighter when set for low Baud.
** Blinks brighter when set for low Baud.
* Interface 12V - DC-DC isolation converter is working - 12V available on 485 interface terminal
* 12V: DC-DC isolation converter is working - 12V available on 485 interface terminal
** Should be as bright as power light on Power module.
** Should be as bright as power light on Power module.
* Interface 5V - interface regulator is working (may be damaged by surges induced to data cable)
* 5V: interface regulator is working (may be damaged by surges induced to data cable)
** Should be as bright as power light on Power module.
** Should be as bright as power light on Power module.