Specific Relay Model Technical Data:
* [[Bell Control Technical Data 2034|Libertas 2034 Technical Data]]
* [[Bell Control Technical Data 3700|Libertas 3700 Technical Data]]


== Connections ==
== Connections ==


=== AC power input ===
=== AC power input ===
All relay panels use single phase power. Clappers and hammers operate between 208 and 240 VAC. Swinging bell motor systems come in three phase and single phase versions.
All striker relay panels use single phase power. Clappers and hammers operate between 208 and 240 VAC. Swinging bell motor systems come in three phase and single phase versions.


Connect a supply of at least 20A to panels with one to three bells. Add 5A per bell that could ring simultaneously (generally no more than six will ring at the same time). Input terminals L1 and L2 accept up to 10 AWG.
Connect a supply of at least 20A to panels with one to three bells. Add 5A per bell that could ring simultaneously (generally no more than six will ring at the same time). Input terminals L1 and L2 accept up to 10 AWG.