| Line 132: | Line 132: | ||
* If the bell seems to be fighting itself to get started, experiment with smaller values of %Start. | * If the bell seems to be fighting itself to get started, experiment with smaller values of %Start. | ||
* If you get ''ErrBlo'' (blocked bell): | * If you get ''ErrBlo'' (blocked bell): | ||
** It may need more pulses to exit the sensor. Try increasing StaImp. | ** It may need more starting pulses to exit the sensor. Try increasing StaImp (number of allowed blind pulses). | ||
** Check that you properly set the ''1Oscillation'' [[#Initialize|above]]. If it is still 900, you did not complete the procedure. [[#Initialize|Do it again]]. | ** Check that you properly set the ''1Oscillation'' [[#Initialize|above]]. If it is still 900, you did not complete the procedure. [[#Initialize|Do it again]]. | ||