Bell Control Technical Data 3700: Difference between revisions

No edit summary
m /* Lights
Line 47: Line 47:
Interface module
Interface module
* Active - indicates the high voltage relays are enabled. Indicated from logic before drive transistor.
* Active - indicates the high voltage relays are enabled. Indicated from logic before drive transistor.
** Active only on when outputs are active. Times out 5 seconds after last output.
** Active only on when outputs are active. Resets at end of concert.
* Power - 12VDC Power supply from 3710 is on and 5V regulator is OK.
* Power - 12VDC Power supply from Power Supply Module is on and 5V regulator is OK.
** Should be as bright as power light on Power module.
** Should be as bright as power light on Power module.
* Test Mode - indicates self test is active. Inputs are ignored.
* Test Mode - indicates self test is active. Inputs are ignored.
Line 56: Line 56:
* Input - indicates that input data addressed to this panel, or
* Input - indicates that input data addressed to this panel, or
** Steady Blink if configuration switch error.
** Steady Blink if configuration switch error.
** Will not blink if incoming note is for this panel, but no module has been addressed for it.
** Will not blink if incoming activation data is for this panel, but no module has been installed for it.
* Output - indicates that this panel is sending status out to controller.
* Output - indicates that this panel is sending status back to the controller.
** Blinks brighter when set for low Baud.
** Blinks brighter when set for low Baud.
* Interface 12V - DC-DC isolation converter is working - 12V available on 485 interface
* Interface 12V - DC-DC isolation converter is working - 12V available on 485 interface terminal
** Should be as bright as power light on Power module.
** Should be as bright as power light on Power module.
* Interface 5V - interface regulator is working (may be damaged by surges induced to data cable)
* Interface 5V - interface regulator is working (may be damaged by surges induced to data cable)
Line 65: Line 65:


Power module
Power module
* Power - 12VDC Power supply is working and AC input within 100-240VAC
* Power - 12VDC Power supply is working and AC input is within 100-240VAC
* Active - indicates the high voltage relays are enabled. Indicates Interface module drive transistor is OK.
* Active - indicates the high voltage relays are enabled. Indicates Interface Module drive transistor is OK.


Output modules
Output modules