== Platinum ==
== Platinum ==
[[File: File:Platinum-connections.png|frameless]]
[[File:Platinum-connections.png|800px|frameless]]


'''Connections'''
=== Platinum Connections ===
* Professional balanced line audio outputs
* Professional balanced line audio outputs
** IMPORTANT: No horn protection on any outputs, inSpire DSP amplifiers or high-pass filter required for horn type loudspeakers
** IMPORTANT: No horn protection on any outputs, inSpire DSP amplifiers or high-pass filter required for horn type loudspeakers
Line 12: Line 12:
** '''MON 1''' - Left inside zone for PA or amplified speaker
** '''MON 1''' - Left inside zone for PA or amplified speaker
** '''MON 2''' - Right inside zone
** '''MON 2''' - Right inside zone
* '''MIDI keyboard'''
* '''MIDI keyboard''' Input
** Keyboard performance recording
** Keyboard performance recording
** Standard MIDI jack on rear panel
** Standard MIDI jack on rear panel
Line 20: Line 20:
* '''LAN''' - Wired Ethernet network interface (wired or wireless - WiFi adapter included)
* '''LAN''' - Wired Ethernet network interface (wired or wireless - WiFi adapter included)
* Optional wired or optical '''tower control''' bells/clock interface
* Optional wired or optical '''tower control''' bells/clock interface
* '''AC Input''' 100-240 VAC 50/60 Hz.
** Ground required for surge suppression.
** Uninterruptible power supply (UPS battery backup) is recommended
*** 400VA - Do not plug amplifier into battery backup receptacle, only surge protection


== Millennium ==
== Millennium ==
[[File: File:Millennium-connections.png|frameless]]
[[File:Millennium-connections.png|800px|frameless]]


'''Connections'''
=== Millennium Connections ===
* Professional balanced line audio outputs
* Professional balanced line audio outputs
** '''OUT A''' - Inside zone for PA system connected
** '''OUT A''' - Inside zone for PA or amplified speaker
** '''OUT B''' - Outside zone with horn protection for outdoor speakers
** '''OUT B''' - Outside zone with horn protection for outdoor speakers
* MIDI keyboard support
* '''MIDI keyboard''' Input
** Keyboard performance recording
** Keyboard performance recording
** Standard MIDI jack on rear panel
** Standard MIDI jack on rear panel
Line 36: Line 40:
* '''LAN''' - Wired Ethernet network interface (optional WiFi available separately)
* '''LAN''' - Wired Ethernet network interface (optional WiFi available separately)
* Optional wired or optical '''tower control''' bells/clock interface
* Optional wired or optical '''tower control''' bells/clock interface
* '''AC Input''' 100-240 VAC 50/60 Hz.
** Ground required for surge suppression.
** Uninterruptible power supply (UPS battery backup) is recommended
*** 400VA - Do not plug amplifier into battery backup receptacle, only surge protection


== Bravo ==
== Bravo ==
[[File: File:Bravo-connections.png|frameless]]
[[File:Bravo-connections.png|800px|frameless]]


'''Connections'''
=== Bravo Connections ===
* Professional balanced line audio outputs
* Professional balanced line audio outputs
** '''OUT A''' - Inside zone for PA system connected
** '''OUT A''' - Inside zone for PA or amplified speaker
** '''OUT B''' - Outside zone with horn protection for outdoor speakers
** '''OUT B''' - Outside zone with horn protection for outdoor speakers
* '''LAN''' - Wired Ethernet network interface
* '''LAN''' - Wired Ethernet network interface
* '''USB''' - for optional WiFi adapter only
* '''USB''' - for optional WiFi adapter only
* '''AC Input''' 100-240 VAC 50/60 Hz.
** Ground required for surge suppression.
** Uninterruptible power supply (UPS battery backup) is recommended
*** 400VA - Do not plug amplifier into battery backup receptacle, only surge protection
== Surge Protection ==
The low power requirements of the carillon system allows the use of an affordable uninterruptable power supply.
* Grounded power receptacles are required
* Separate SURGE ONLY receptacles should be used for amplifiers
* Back up receptacles should only be used for the carillon ringing controller
Suggested UPS
* [https://tripplite.eaton.com/bc-personal-120v-350va-180w-standby-ups-ultra-compact-desktop-6-outlets~BC350 Tripp Lite BC350] around [https://www.amazon.com/Tripp-Lite-BC350-Desktop-Battery/dp/B000B8MFI6 $60]


[[Category:AX Products]]
[[Category:AX Products]]
[[Category:AX Manual]]
[[Category:AX Manual]]

Latest revision as of 14:47, 26 May 2023

Help ← Back to Manual Contents


Platinum

Platinum-connections.png

Platinum Connections

  • Professional balanced line audio outputs
    • IMPORTANT: No horn protection on any outputs, inSpire DSP amplifiers or high-pass filter required for horn type loudspeakers
    • OUT A - Outside zone
    • OUT B - Outside zone (optional directional control)
    • MON 1 - Left inside zone for PA or amplified speaker
    • MON 2 - Right inside zone
  • MIDI keyboard Input
    • Keyboard performance recording
    • Standard MIDI jack on rear panel
      • Supports two channels (2nd keyboard dedicated to harp-bell instruments)
    • USB connection will accept a USB controller or MIDI interface
  • Amplifier control supports 2 inSpire amplifiers with fault detection
  • LAN - Wired Ethernet network interface (wired or wireless - WiFi adapter included)
  • Optional wired or optical tower control bells/clock interface
  • AC Input 100-240 VAC 50/60 Hz.
    • Ground required for surge suppression.
    • Uninterruptible power supply (UPS battery backup) is recommended
      • 400VA - Do not plug amplifier into battery backup receptacle, only surge protection

Millennium

Millennium-connections.png

Millennium Connections

  • Professional balanced line audio outputs
    • OUT A - Inside zone for PA or amplified speaker
    • OUT B - Outside zone with horn protection for outdoor speakers
  • MIDI keyboard Input
    • Keyboard performance recording
    • Standard MIDI jack on rear panel
      • Single MIDI channel support (carillon or split on one keyboard)
    • USB connection will accept a USB MIDI keyboard
  • Amplifier control for a single inSpire amplifier
  • LAN - Wired Ethernet network interface (optional WiFi available separately)
  • Optional wired or optical tower control bells/clock interface
  • AC Input 100-240 VAC 50/60 Hz.
    • Ground required for surge suppression.
    • Uninterruptible power supply (UPS battery backup) is recommended
      • 400VA - Do not plug amplifier into battery backup receptacle, only surge protection

Bravo

Bravo-connections.png

Bravo Connections

  • Professional balanced line audio outputs
    • OUT A - Inside zone for PA or amplified speaker
    • OUT B - Outside zone with horn protection for outdoor speakers
  • LAN - Wired Ethernet network interface
  • USB - for optional WiFi adapter only
  • AC Input 100-240 VAC 50/60 Hz.
    • Ground required for surge suppression.
    • Uninterruptible power supply (UPS battery backup) is recommended
      • 400VA - Do not plug amplifier into battery backup receptacle, only surge protection

Surge Protection

The low power requirements of the carillon system allows the use of an affordable uninterruptable power supply.

  • Grounded power receptacles are required
  • Separate SURGE ONLY receptacles should be used for amplifiers
  • Back up receptacles should only be used for the carillon ringing controller

Suggested UPS