IntelliSwing rotary sensor setup: Difference between revisions
hookup and linear rotary sensors |
P-regulator ideals |
||
| (11 intermediate revisions by 2 users not shown) | |||
| Line 69: | Line 69: | ||
Either a slotted code wheel with sensors are mounted to the motor or a rotary sensor assembly is coupled to the swinging bell axle for this system to accurately measure the swinging angle and direction. | Either a slotted code wheel with sensors are mounted to the motor or a rotary sensor assembly is coupled to the swinging bell axle for this system to accurately measure the swinging angle and direction. | ||
The label on the motor control computer PCB should read 'SENSOR.' For motors without a code wheel and sensor, a proximity switch is used for motion feedback. In that case, verify that the CPU chip on the intelliSwing Precision motion controller has a label that reads 'PERIOD' and use the [[MagForce_motor_system_installation# | The label on the motor control computer PCB should read 'SENSOR.' For motors without a code wheel and sensor, a proximity switch is used for motion feedback. In that case, verify that the CPU chip on the intelliSwing Precision motion controller has a label that reads 'PERIOD' and use the [[MagForce_motor_system_installation#Programming_Procedure_%28PERIOD_proximity%29|MagForce PERIOD programming procedure]]. | ||
For each bell we need to calculate the value for Transmission. Take the diameter in inches of the wheel (on the rim where the chain runs) ''multiplied by'' 6.28 (π ''divided'' by the chain pitch, generally 1/2 inch) and ''divide'' the result by the number of teeth on the cog. | For each bell we need to calculate the value for Transmission. Take the diameter in inches of the wheel (on the rim where the chain runs) ''multiplied by'' 6.28 (π ''divided'' by the chain pitch, generally 1/2 inch) and ''divide'' the result by the number of teeth on the cog. | ||
| Line 90: | Line 90: | ||
Connect the programming terminal and turn on panel power. The right cursor button will take you through the settings for each bell in the system. From the status window, shown below, you can cursor left to select another bell. To change settings you can increment/decrement using the up and down arrow buttons, or input the value with the numeric buttons and save it with the EXE button. | Connect the programming terminal and turn on panel power. The right cursor button will take you through the settings for each bell in the system. From the status window, shown below, you can cursor left to select another bell. To change settings you can increment/decrement using the up and down arrow buttons, or input the value with the numeric buttons and save it with the EXE button. | ||
==== Display ==== | |||
The two line programming status screen should look like this (first and fourth lines are our labels): | After changing parameters, try always to return to the status screen when running the bell. The two line programming status screen should look like this (first and fourth lines are our labels): | ||
Swing Angle Motor Pulse Time Tempo | Swing Angle Motor Pulse Time Tempo | ||
| Line 100: | Line 100: | ||
When the bell is swinging, the display will indicate the current Swing Angle to the nearest tenth of a degree, the Motor Pulse time in milliseconds, the Tempo in beats per minute, the motor RPM (for rotary) and "*" will blink when feedback from the sensor occurs. The Ideal Pulse is the time in milliseconds that will maintain the desired swinging angle. Status will be ''Start, Stop, Restart, StartP, Calc-P'' or ''Calc-Imp,'' indicating the swinging/calculation mode. | When the bell is swinging, the display will indicate the current Swing Angle to the nearest tenth of a degree, the Motor Pulse time in milliseconds, the Tempo in beats per minute, the motor RPM (for rotary) and "*" will blink when feedback from the sensor occurs. The Ideal Pulse is the time in milliseconds that will maintain the desired swinging angle. Status will be ''Start, Stop, Restart, StartP, Calc-P'' or ''Calc-Imp,'' indicating the swinging/calculation mode. | ||
=== | ==== Keypad ==== | ||
* Use the left and right cursor buttons to move through the setting screens. | |||
* Use the numeric buttons to enter parameter values, then press EXE to save them | |||
* Use up and down cursor buttons to make small changes to the displayed value | |||
** Cursor up will change the Polarity parameter to Negative | |||
** Cursor down will change the Polarity parameter to Positive | |||
* The ON button starts and stops the motor, and clears errors | |||
Check operation of the sensor. Move the bell by hand and you should hear the phase reversing relay click when the bell reverses direction. | === First! === | ||
Check operation of the sensor. Move the bell by hand and you should hear the phase reversing relay click when the bell reverses direction when the '''D''' light on the relay board goes on and off. | |||
=== Set Swing Angle and other initial parameters === | === Set Swing Angle and other initial parameters === | ||
| Line 196: | Line 201: | ||
*Bell Number (1 is the largest bell) | *Bell Number (1 is the largest bell) | ||
*Tempo (speed of ringing in beats per minute) | *Tempo (speed of ringing in beats per minute) | ||
** read this from the top right of the status screen while the bell is in the Swing mode | |||
*Swing Angle (intended angle) | *Swing Angle (intended angle) | ||
*Transmission (rotary cog to wheel ratio) | *Transmission (rotary cog to wheel ratio) | ||
*%Start ( | ** 22.8 for linear MagForce motors | ||
*%Brake (portion of swing angle | *%Start (starting pulse maximum length before sensor is detected) | ||
*Polarity ( | *%Brake (portion of swing angle for braking action when turning off the bell) | ||
*Polarity (initial direction +/- effectively reverses motor leads U and V) | |||
*Brake Angle (angle where brake switches from Power Brake 1 to 2) | *Brake Angle (angle where brake switches from Power Brake 1 to 2) | ||
*PowerStaSwi (power reduction | *PowerStaSwi (power reduction for over-powered motors) | ||
** 9 - No soft start - full power - mechanical shocks may damage motor mounts | |||
** 8 - (default) Soft start - full power | |||
** 1 to 7 - Soft start - reduced power | |||
*Power Brake 1 (first brake current limit) | *Power Brake 1 (first brake current limit) | ||
*Power Brake 2 (second brake current limit) | *Power Brake 2 (second brake current limit) | ||
*MaxAmpl (maximum angle before error and shutdown) | *MaxAmpl (maximum angle before error and shutdown) | ||
*P-Regulator - Proportional regulation factor (amount added/subtracted to pulse to compensate for under/overshoot) | *P-Regulator - Proportional regulation factor (amount added/subtracted to pulse to compensate for under/overshoot) | ||
** Ideal values are close to 50 for a well matched motor. If they are much lower, try reducing the PowerStaSwi setting. | |||
*I-Regulator - Ideal pulse - (Will be 0 after automatic calculations. Manually set this to zero after manual experimentation, but make a record of what was set) | *I-Regulator - Ideal pulse - (Will be 0 after automatic calculations. Manually set this to zero after manual experimentation, but make a record of what was set) | ||
** read calculated I from the bottom center of the status screen | |||
*Pos-Impulse (Position of the motor impulse in the sweep of the bell; 0=home 100=turnaround) | *Pos-Impulse (Position of the motor impulse in the sweep of the bell; 0=home 100=turnaround) | ||
** must be 0 for linear MagForce motors | |||
*Assymmetric (Proportion of motor pulse for forward/backward balance; 50 = equal, 100 or 0 = unidirectional drive) | *Assymmetric (Proportion of motor pulse for forward/backward balance; 50 = equal, 100 or 0 = unidirectional drive) | ||
== After setup complete == | == After setup complete == | ||
Disconnect the programming terminal. The front panel switches and the Chime Master relays will not activate the motors while the programming terminal is connected. | |||
== Troubleshooting == | |||
=== Clear all programs === | |||
To restore the panel to the factory default settings (all bells), | |||
* Power on the panel with the programmer plugged in | |||
* Click the left button until you reach the Language select screen | |||
* Press the DEL button. The display will say STOP. | |||
=== Errors === | |||
When the system is displaying an error, it will not show sensor feedback when you move the bell by hand. It will not activate the braking action if the bell is swinging. | |||
* To clear the error, Press the ON button so that the display reads STOP | |||
==== ErrBlo ==== | |||
If the screen shows 'ErrBlo' on the lower right of the screen, the system thinks the bell is not moving as expected. This can be caused by: | |||
* Loose connections to the motor or the sensor | |||
* Motor is mis-wired | |||
* Sensor is mis-wired | |||
* Motor is undersized or mounted in a way that prevents it from generating enough torque. | |||
==== ErrAmp ==== | |||
If the screen shows 'ErrAmp' on the lower right of the screen, the system detected that the bell went higher than the selected MaxAmpli setting. Every time you modify the Swinging Angle setting, the system will add five degrees to that setting for MaxAmpli. To avoid errors while setting up the system, set MaxAmpli to 90 degrees, or a safe angle in case of overshoot. | |||
=== Sensor Test === | |||
While the screen shows 'STOP' you can move the bell by hand. The D light on the motor output board should blink to indicate the direction the bell is swinging. The top left number on the terminal display should show the angle the system thinks the bell is swinging. If you do not get these indications, check the sensor wiring. | |||
[[Category:Installation]] | [[Category:Installation]] | ||
[[Category:Bell automation]] | [[Category:Bell automation]] | ||