MagForce motor system installation: Difference between revisions

make clear this setup method is for PERIOD proximity sensors
 
Line 94: Line 94:
The MagForce control panel for single phase will have a capacitor on the output between outputs ''U'' and ''V''. If the motor is sized to require an overload protector, the ''L1'' connection to the triac input will be routed in a serpentine fashion through the three overload circuits. This is required to prevent trips caused by the missing phase detection.
The MagForce control panel for single phase will have a capacitor on the output between outputs ''U'' and ''V''. If the motor is sized to require an overload protector, the ''L1'' connection to the triac input will be routed in a serpentine fashion through the three overload circuits. This is required to prevent trips caused by the missing phase detection.


== Programming Procedure ==
== Programming Procedure (PERIOD proximity) ==
IMPORTANT:
IMPORTANT:
* If a rotary encoder is installed on the headstock spindles (chip on control board has a label marked '''SENSOR''')
* If a rotary encoder is installed on the headstock spindles (chip on control board has a label marked '''SENSOR''')