Bell Ringing Components: Difference between revisions

spec - spec link
m spec - spec link
Line 28: Line 28:
<br>When announcing times of prayer or mourning, a toll of the bell while it is stationary is more appropriate.  
<br>When announcing times of prayer or mourning, a toll of the bell while it is stationary is more appropriate.  


The diagram shows such a hammer (I) actuated by an electromagnet (J) that allows an [http://www.chimemaster.com/libertas electric bell control system] to sound the hour, announce prayer times or count the age of the person being memorialized.
The diagram shows such a hammer (I) actuated by an electromagnet (J) that allows an [[Libertas_master_clock_controller|Libertas bell control system]] to sound the hour, announce prayer times or count the age of the person being memorialized.


=== Stationary Bell ===
=== Stationary Bell ===
Line 49: Line 49:
=== Electronics ===
=== Electronics ===
==== Automation controller ====
==== Automation controller ====
Modern bell ringing equipment makes use of the latest electronic technology to control bell ringing schedules, ringing patterns and music as well as providing time synchronization and convenient remote control options.
The [[Libertas_master_clock_controller|Libertas bell control system]] makes use of the latest electronic technology to control bell ringing schedules, ringing patterns and music as well as providing time synchronization and convenient remote control options.


==== Power switching ====
==== Power switching ====
Advanced power switching panels ensure that high currents are applied to the ringing components only as long as it is needed. This keeps the tower safe from electric shock, prevents actuator overheating, and damage to the bell.
Advanced power switching panels ensure that high currents are applied to the ringing components only as long as it is needed. This keeps the tower safe from electric shock, prevents actuator overheating, and damage to the bell.


High voltage circuits should be switched through dry mechanical relay components because even the most advanced solid state circuits leak some currents. Solid state power switching is only acceptable when a dry master contactor enables the high voltage to the individual outputs only during ringing.
High voltage circuits should be switched through dry mechanical relay components because even the most advanced solid state circuits leak some currents. Solid state power switching is only acceptable when a dry contact master relay enables the high voltage to the individual outputs only during ringing.


[[Category:Campanology]]