Clock wiring 34DMI24: Difference between revisions

Clock movement - corrected output diagram labels
re-order according to outputs
Line 26: Line 26:
The clock movement inputs are generally labeled as follows:
The clock movement inputs are generally labeled as follows:


;COM
:Common is the return current for L1 and L2 (A terminal on the hookup diagram)
;L1
;L1
:This is the 24VAC odd minute input (B output on the hookup diagram)
:This is the 24VAC odd minute input (B output on the hookup diagram)
;L2
;L2
:This is the 24VAC even minute input (C output on the hookup diagram)
:This is the 24VAC even minute input (C output on the hookup diagram)
;COM
:Common is the return current for L1 and L2 (A terminal on the hookup diagram)


Connect the clock with suitable cable (typically 16 AWG Belden 5202UE) to the controller output terminals.