Libertas bell control hookup: Difference between revisions
Line 12: | Line 12: | ||
=== Data Cable === | === Data Cable === | ||
A twisted pair data cable is required and typically we use a minimum of CAT5 with RJ45 terminations. The pinout of the terminations and wire colors is the standard B style pin out. The following colors appear top to bottom when cable exits the housing to the left and the clip is away from you: | A twisted pair data cable is required and typically we use a minimum of CAT5 with RJ45 terminations. The pinout of the terminations and wire colors is the standard B style pin out. The following colors appear top to bottom when cable exits the housing to the left and the clip is away from you: | ||
[[File:CAT5-Termination.png|400px|thumb|right|CAT5 RJ45 Termination]] | |||
1 Orange/White - 12VDC negative | 1 Orange/White - 12VDC negative | ||
2 Orange solid - 12VDC negative | 2 Orange solid - 12VDC negative |
Revision as of 19:57, 22 February 2017
Hookup
Click the following diagram links to open in your browser or right click to download and save:
- Single output bell controller hookup (PDF download) This relay is in a plastic box and is not weather resistant.
- Three output bell controller hookup (PDF download) NEMA relay panel for three stationary bells.
- Four output bell controller hookup (PDF download) NEMA relay panel for four stationary bells.
- T1M3 - NEMA relay panel with four outputs for three swinging bells with a single tolling hammer on bell 1.
Data Cable
A twisted pair data cable is required and typically we use a minimum of CAT5 with RJ45 terminations. The pinout of the terminations and wire colors is the standard B style pin out. The following colors appear top to bottom when cable exits the housing to the left and the clip is away from you:
1 Orange/White - 12VDC negative 2 Orange solid - 12VDC negative 3 Green/White - Data A (RS485) 4 Blue solid - Status B (RS485) 5 Blue/White - Status A (RS485) 6 Green solid - Data B (RS485) 7 Brown/White - 12VDC positive 8 Brown solid - 12VDC positive
Crimping Procedure
- Cut cable to length
- Strip 1-1/2" of outer jacket from cable without nicking conductors.
- Pull the jacket back from the end as much as possible.
- Fan-out conductor pairs, orange top, green, blue brown bottom.
- Untwist green, arrange green/white above blue, solid green below.
- Untwist blue, orient solid above blue/white
- Untwist orange and brown pairs, keep solids below the striped.
- Flatten the fan and bring together keeping the order shown above.
- Use scissors to cut the conductors about 3/4" from jacket.
- Double check wire order and insert conductors fully into the RJ45 connector as shown.
- Crimp the connector using an RJ45 crimping tool.
Relay panel technical information
Lights and test buttons
At the top of the relay panel is a square board with three buttons with four lights at the top edge.
The four lights are labeled:
Power - Data - Fault - Status
The buttons may be labeled:
Reset - Test - Step
At the bottom of this board, and sometimes installed on an auxiliary board attached with a ribbon cable, are one inch square output modules mounted vertically (four outputs on the main board, twelve outputs on the auxiliary board). For tolling outputs, there will be two timer adjustment controls. For motorized ringers there will not be adjustments. At the top of these boards is a green light that indicates the output is on. At the bottom of the board is a red light that indicates the output is driving a short circuit.
Test mode
Hold the Test button (under the Data light) while momentarily clicking the Reset button (under the Power light). After the Fault light blinks you can let go of the Test button. The Data light should remain lit to indicate the panel is in the self-test mode.
Press the Step button to sequence through the outputs. The tolling outputs will ring first then any motorized outputs will follow. Note that after ringing the Motorized outputs, the toll outputs will may locked out (hammer protect mode). If you need to test the tollers again, repeat the procedure above to reset the test mode (after the bells have ceased to swing).
To repeat an output that you have stepped to, press the Test button to repeat it. This is useful for testing motorized outputs that time out after a second or so.
Exit test mode
The panel will reset to the standby mode in a couple of minutes. For immediate reset, press the Reset button so that the Data light goes out.
Pulse Adjustments
Each timer board has two adjustment potentiometers. The top adjustment sets the length of the pulse and the bottom adjustment sets the maximum repeat rate. For both cases, clockwise adjustments shorten the pulse and allows smaller bells to repeat faster.
If the lower potentiometer is adjusted counter clockwise more than the upper adjustment, the ON pulse will be shortened to allow faster repeats.
Pulse setting procedure for large tolling bells
- Set the top adjustment fully clockwise
- Set the bottom adjustment fully counter-clockwise
- Turn top adjustment counterclockwise until the ringing does not get any louder
Pulse setting procedure for small chime/carillon bells
- Set both adjustments fully clockwise (short pulse)
- Turn top adjustment counterclockwise until the ringing does not get any louder
- If the top adjustment is fully counterclockwise and you can get the bell to ring louder by turning the bottom adjustment farther then continue adjusting the bottom adjustment until the desired performance is obtained.
Troubleshooting
Fuse blows
Test Open Output
Disconnect output wires from PCB for the bell that blows fuse. If fuse still blows without anything connected, the rectifier is probably at fault. Most panels have socketed rectifiers that can be replaced. Be sure to align the angled corner (positive lead) correctly when inserting the replacement.
Test Alternate Output
If the output in question does not blow the fuse when its output is not connected, try connecting the bell to another output (lower numbered output for high current fuse). If the other output fuse blows there is a problem with the striker or wiring.