Libertas LX Specification: Difference between revisions
Basic to LX specification changes |
|||
| Line 1: | Line 1: | ||
<div style="font-size:84%">'''[http://www.ChimeMaster.com Home] > [[Chime_Master_Help|Help]] > [[Automation_specifications|Automation Specifications]]'''</div><br /> | <div style="font-size:84%">'''[http://www.ChimeMaster.com Home] > [[Chime_Master_Help|Help]] > [[Automation_specifications|Automation Specifications]]'''</div><br /> | ||
[[File: | [[File:LibertasLX.png|400px|thumb|right|Libertas LX<sup>™</sup>]] | ||
== Description == | == Description == | ||
The Chime Master | The '''Chime Master Libertas LX''' is an automatic bell control system for one to six bells. This product is designed and built specifically for the purpose of automatic church bell ringing. | ||
Included weekly scheduling features provide flawless performance year after year without intervention for most congregations. Additional flexibility can be added with the optional Premium Management software for automated schedule changes. | Included weekly scheduling features provide flawless performance year after year without intervention for most congregations. Additional flexibility can be added with the optional Premium Management software for automated schedule changes. | ||
| Line 28: | Line 28: | ||
** Westminster (5-bells) | ** Westminster (5-bells) | ||
** Westminster (4-bells) | ** Westminster (4-bells) | ||
** Christus Vincit (6-bells) | ** Christus Vincit (requires 6-bells of specific pitch) | ||
** Warren | ** Warren | ||
** Bigelow | ** Bigelow | ||
| Line 49: | Line 49: | ||
* PIN code keypad access security | * PIN code keypad access security | ||
*Automatic Daylight time switching | *Automatic Daylight time switching | ||
* | *Wall mount standard | ||
** Table top or Rack mounting options | |||
** | |||
== Options == | == Options == | ||
| Line 65: | Line 59: | ||
** Automatic correction of clock dials after power interruption | ** Automatic correction of clock dials after power interruption | ||
** Clock status monitoring and error display | ** Clock status monitoring and error display | ||
* | * Four conductor data cable to tower | ||
** System powered from tower up to 300 feet | |||
** Optional 100-240VAC to 12VDC power adapter | |||
** | |||
** Optional | |||
== Connections == | == Connections == | ||
* Data | * Data | ||
** | ** Tower CAT5 or dual twisted pair cabling | ||
** | *** T - Data +/- to tower accessories | ||
*** Direct connection to Chime Master bell relay panels | *** P - Power +/- from tower | ||
**** required to power interface even if using local power supply input | |||
*** Chassis Ground - connect to local safety ground | |||
** Direct connection to Chime Master bell relay panels | |||
** Supports Chime Master clock movements | |||
== Physical == | == Physical == | ||
* | * Without brackets or stand | ||
** | ** 5-1/4 inches high, 9 inches wide, 2-1/4 inches deep | ||
** 2 lbs weight | |||
** | * With tabletop stand | ||
* | ** 5-3/4 inches high, 9 inches wide, 5-1/2 inches deep | ||
** | ** 2-3/4 pounds weight | ||
* Wall mount | |||
** | ** 5-1/4 inches high, 9 inches wide, 2-3/4 deep | ||
* | ** 3 pounds weight | ||
** | * Rack mount | ||
* | ** 5-1/4 inches (3U) high, 19 inches wide, 2-1/4 inches deep | ||
* | ** 3-1/4 pounds weight | ||
** | |||
** | |||
[[Category:Automation Specification]] | [[Category:Automation Specification]] | ||