Libertas bell control hookup: Difference between revisions

Line 57: Line 57:
* L2 - Red
* L2 - Red
* L3 - Blue (when three phase power is used for motors)
* L3 - Blue (when three phase power is used for motors)
* DC striker outputs (polarity not important) - Yellow
* T1, T2, etc. DC striker outputs (polarity not important) - Yellow
* High voltage, low current control output to external contactors (switched L1) - Violet
* M1, M2, etc. Motor contactor outputs (high voltage, low current) - Violet
* COM - may be jumpered to L1 at the factory - Black


Secondary low voltage control wiring shall be 18 AWG with 300V insulation in the following colors:
Secondary low voltage control wiring shall be 18 AWG with 300V insulation in the following colors:
* Negative / Ground - Black
* Negative DC - Black
* Positive DC control - Red
* Positive DC control - Red