=== Wiring color codes === | |||
All primary wiring shall be 16 AWG or greater, stranded with 600V insulation in the following colors: | |||
* Earth protective ground - Green | |||
* Neutral (not generally required) - White | |||
* L1 - Black | |||
* L2 - Red | |||
* L3 - Blue (when three phase power is used for motors) | |||
* DC striker outputs (polarity not important) - Yellow | |||
* Control output to other high current switching (switched L1) - Violet | |||
Secondary low voltage control wiring shall be 18 AWG with 300V insulation in the following colors: | |||
* Negative / Ground - Black | |||
* Positive DC control - Red | |||