=== Wiring color codes ===
All primary wiring shall be 16 AWG or greater, stranded with 600V insulation in the following colors:
* Earth protective ground - Green
* Neutral (not generally required) - White
* L1 - Black
* L2 - Red
* L3 - Blue (when three phase power is used for motors)
* DC striker outputs (polarity not important) - Yellow
* Control output to other high current switching (switched L1) - Violet
Secondary low voltage control wiring shall be 18 AWG with 300V insulation in the following colors:
* Negative / Ground - Black
* Positive DC control - Red
=== Lights and test buttons ===
=== Lights and test buttons ===
At the top of the relay panel is a square board with three buttons with four lights at the top edge.
At the top of the relay panel is a square board with three buttons with four lights at the top edge.