Libertas bell control hookup: Difference between revisions
Hookup - cat5 procedure |
|||
| Line 1: | Line 1: | ||
<div style="font-size:84%">'''[http://www.ChimeMaster.com Home] > [[Chime_Master_Help|Help]] > [[Installation_documentation|Installation]] '''</div><br /> | <div style="font-size:84%">'''[http://www.ChimeMaster.com Home] > [[Chime_Master_Help|Help]] > [[Installation_documentation|Installation]] '''</div><br /> | ||
== | == Hookup == | ||
Click to open in your browser or right click to download and save: | Click to open in your browser or right click to download and save: | ||
| Line 9: | Line 9: | ||
* [[Media:2034T4220W2.pdf|Four output bell controller hookup (PDF download)]] | * [[Media:2034T4220W2.pdf|Four output bell controller hookup (PDF download)]] | ||
* Relay panel for up to 16 bells | * Relay panel for up to 16 bells | ||
=== Data Cable === | |||
A twisted pair data cable is required and typically we use a minimum of CAT5 with RJ45 terminations. The pinout of the terminations and wire colors (B style pinout). The following colors appear top to bottom when cable exits the housing to the left and the clip is away from you: | |||
1 Orange/White - 12VDC negative | |||
2 Orange solid - 12VDC negative | |||
3 Green/White - Data A (RS485) | |||
4 Blue solid - Status B (RS485) | |||
5 Blue/White - Status A (RS485) | |||
6 Green solid - Data B (RS485) | |||
7 Brown/White - 12VDC positive | |||
8 Brown solid - 12VDC positive | |||
'''Crimping Procedure''' | |||
# Cut cable to length | |||
# Strip 1-1/2" of outer jacket from cable without nicking conductors. | |||
# Pull the jacket back from the end as much as possible. | |||
# Fan-out conductor pairs, orange top, green, blue brown bottom. | |||
# Untwist green, arrange green/white above blue, solid green below. | |||
# Untwist blue, orient solid above blue/white | |||
# Untwist orange and brown pairs, keep solids below the striped. | |||
# Flatten the fan and bring together keeping the order shown above. | |||
# Use scissors to cut the conductors about 3/4" from jacket. | |||
# Double check wire order and insert conductors fully into the RJ45 connector as shown. | |||
# Crimp the connector using an RJ45 crimping tool. | |||