70V Line Speaker Wiring: Difference between revisions

mNo edit summary
added transformer wiring info
Line 36: Line 36:
*Insertion Loss: As much as 20% of the amplifier's power is wasted through the transformers. This figure should be accounted for and compared to when calculating the losses encountered through various sizes of low impedance wiring.
*Insertion Loss: As much as 20% of the amplifier's power is wasted through the transformers. This figure should be accounted for and compared to when calculating the losses encountered through various sizes of low impedance wiring.
*Capacitance: To handle higher powers, transformers have to be scaled up in size. The added capacitance begins to attenuate high frequencies.
*Capacitance: To handle higher powers, transformers have to be scaled up in size. The added capacitance begins to attenuate high frequencies.
== Transformers ==
=== Atlas 70 Transformer wiring ===
Internally mounted transformers in Atlas PD-60T drivers have the following color code:
Red - Voice Coil Negative
White - Voice Coil Positive
Black - Common input terminal
Yellow - 16 Ohm input terminal
Orange- 60W input terminal
Blue - 40W input terminal
Green - 20W input terminal
Gray - 10W input terminal
Violet - 5W input terminal
Brown - 2.5W input terminal
=== San Ming 70 Transformer wiring ===
Internally mounted transformers in San Ming drivers have the following color code:
Top terminals - Voice Coil
Brown and Green - 40W inputs
Blue and Gray - 30W inputs
Orange and Red - 20W inputs
Violet and White - 10W inputs