m Reverted edit by Charles Barkley (talk) to last revision by Rickwhite
Tag: Rollback
 
(4 intermediate revisions by 2 users not shown)
Line 14: Line 14:
== Advantages ==
== Advantages ==
* Faster repeat times (should be used with our suspension cable stabilizers)
* Faster repeat times (should be used with our suspension cable stabilizers)
* Quieter operation (especially with removal of old reversing switch mechanism)
* Simple Installation
* Simple Installation
* Spark free operation
* Spark free operation
Line 21: Line 22:


== Installation ==
== Installation ==
[[File:Striker3861.jpg|150px|frameless|right|Deagan 67 Hookup]]
* Remove old relay from top of the Deagan 67 action.
* Remove old relay from top of the Deagan 67 action.
** Optionally remove bottom contacts and actuating arm to reduce friction.
** Optionally remove bottom contacts and actuating arm to reduce friction and noise.
* Move coil return leads to positive terminal block (module coil outputs are negative)
* Move coil return leads to positive terminal block (module coil outputs are negative)
* Move the head toward the chime. Replace the retraction cup with the new cup. Orient the cup so that the sensor cable exits the top. Tighten the cup bolt.
* Move the head toward the chime. Replace the retraction cup with the new cup. Orient the cup so that the sensor cable exits the top. Tighten the cup bolt.

Latest revision as of 16:53, 20 July 2026

A solid state replacement for the original Deagan electro-mechanical relay module used on the 67 type Tower Chime action.

Deagan 67 SS Action Controller
Deagan 67 SS Action Controller

Features

  • High current coil outputs with active back-EMF quenching
    • Optional third output for 67-O type Action
  • Optical ram position sensors (replacement retract cup)
  • Reverse polarity warning light
  • Adjustable ram thrust power (volume control)
  • Buttons for testing
  • Supplied with new sensor retraction cup with new felts and leather bumpers

Advantages

  • Faster repeat times (should be used with our suspension cable stabilizers)
  • Quieter operation (especially with removal of old reversing switch mechanism)
  • Simple Installation
  • Spark free operation
  • No complicated contact adjustments
  • Stuck-input protection
  • Low current actuation input

Installation

Deagan 67 Hookup
Deagan 67 Hookup
  • Remove old relay from top of the Deagan 67 action.
    • Optionally remove bottom contacts and actuating arm to reduce friction and noise.
  • Move coil return leads to positive terminal block (module coil outputs are negative)
  • Move the head toward the chime. Replace the retraction cup with the new cup. Orient the cup so that the sensor cable exits the top. Tighten the cup bolt.
  • Mount new module to the top of the action using the supplied bracket (terminal labels will be right-reading viewed from chime end).
  • Connect positive and negative 48V as shown.
    • Briefly, power the system and be sure the POLARITY REVERSED light does not come on.
  • Connect the coil leads to the output terminals. Strike coil is the large bobbin at the chime end. Retract coil is at the rear. Optional O coil is the middle coil.
  • Connect the action signal lead from the main relay to ACTUATION INPUT.

Testing

  • Press the TEST ACTION button to test the striker.
  • Press the TEST MODE button to select the test mode (1 to 3 times)
  • Press the TEST MODE button to cancel tests
  • Adjust the THRUST control clockwise for longer strike pulses. Reducing THRUST allows faster repeat times and lower chime ringing intensity.

Test Modes

  • ERROR/MODE light not blinking - single strike
  • ERROR/MODE light blinking once - 60 BPM for five minutes
  • ERROR/MODE light blinking two times - 120 BPM for five minutes
  • ERROR/MODE light blinking three times - 150 BPM for ten strikes

Error indications

  • POLARITY REVERSED light indicates the motor generator or power supply leads are reversed.
    • If coils are connected while reversed polarity voltage is supplied, the module will be damaged.
    • Always verify polarity before connecting the action coils.
  • ERROR light blinks steadily: The actuation input is stuck. Check for shorted keyboard or relay contacts.
  • ERROR light on solid: Sensor error or strike cycle took longer than expected. Check connections and lubricate action.