Clock wiring 34DMI24: Difference between revisions

(created)
 
(illustration)
Line 8: Line 8:


== Connections ==
== Connections ==
[[File:34DMI24-illustration.png|frameless|right|600px]]
=== Power requirements ===
=== Power requirements ===
;Input voltage
;Input voltage

Revision as of 19:29, 25 September 2019

Part numbers
2034D-MI-24 - For 2206 bell control heads
2134D-MI-24 - For carillons and musical bell controls

This clock control panel provides 24VAC Minute Impulse signals to compatible clock movements.

PDF Hookup diagram

Connections

34DMI24-illustration.png

Power requirements

Input voltage
120 VAC

Power may be supplied either with a power cord plugged into a 120VAC socket or via conduit from the breaker box.

Data connections

One or two RJ jacks for a CAT5 type data cable are on the circuit board at the left side of the control box.

A single jack is provided when tower bells are not used. The cable from this jack goes to the Tower Control output of the Chime Master controller/carillon.

Two jacks are installed when the controller is used with a bell control panel. The right hand jack goes to the controller/carillon and the left hand jack daisy chains the data to the tower bells panel.

Clock movement

The clock movement inputs are generally labeled as follows:

L1
This is the 24VAC odd minute input (A output on the hookup diagram)
L2
This is the 24VAC even minute input (B output on the hookup diagram)
COM
Common is the return current for L1 and L2 (C terminal on the hookup diagram)

Connect the clock with suitable cable (typically 16 AWG) to the controller output terminals.

Testing

New installations will be installed with the clock hands pointing straight up. When upgrading an existing clock system you can set the carillon/controller to the position of the dial hands.

On the controller, navigate to the System Setup Menu: Set System Clock menu and press ENTER. If the time displayed is correct, press CANCEL.

The next screen should say: Tower Clock Dial Hands Indicate: 12:00.

Use the cursor buttons to adjust the time to match what the hands are pointing to, then press ENTER.

The hands will move fast to catch up to the current time

If the dial is one minute off

If the system can not adjust the clock to the exact minute, then the Odd and Even outputs are reversed. There are jumpers on the movement to correct this, but it may be easier to reverse the two output wires in the controller.